Hebei Dehuike Pump Industry Co., Ltd. is one of the most reliable manufacturers and suppliers of is end suction centrifugal pump in China. With abundant experience, we are committed to providing high quality customized pumps with competitive price. Welcome to wholesale bulk is end suction centrifugal pump for sale here from our factory. Also, pricelist is available.
Introduction - Standardized ISO 2858 Architecture, Hydraulic Principles & Global Fluid Handling Standards
Within contemporary municipal engineering, raw water supply networks, industrial utility rooms, and agricultural conveyance mains, the IS End Suction Centrifugal Pump stands as an internationally recognized benchmark for single-stage rotodynamic liquid pressurization. Formulated around the globally accepted ISO 2858 mechanical standard, this horizontal foot-mounted pumping platform establishes strict geometric uniformity for suction and discharge nozzle dimensions, center-line elevations, and bolt-hole spacing. Fluid intake follows a direct axial path, drawing liquid smoothly into the rotating impeller hub before expelling it radially through precision-contoured volute waterways, where kinetic velocity energy transitions efficiently into sustained static head pressure.
Processing plants, irrigation canal networks, and district heating plants depend on predictable continuous-duty pumping machinery that eliminates unplanned shutdowns. Non-standardized pump footprints frequently impose severe engineering bottlenecks during equipment retrofits, requiring costly foundation alterations and piping adjustments. The universal ISO 2858 framework resolves this vulnerability by enabling seamless mechanical interchangeability. Furthermore, the specialized hydraulic profiling within the volute casing mitigates eddy losses, suppresses acoustic vibration, and provides steady hydraulic delivery across wide duty envelopes.
To control operating budgets, modern facility planners prioritize total lifecycle electricity expenditure over initial capital cost. Because utility pumps frequently consume electrical power exceeding their acquisition value within several months of round-the-clock service, maximizing mechanical conversion efficiency at the Rated Optimal Efficiency Point (BEP) is an absolute design priority. The horizontal single-stage IS End Suction Centrifugal Pump achieves this financial and environmental objective through an enclosed radial flow wheel, balanced axial thrust design, and an accessible back-pull-out architecture that drastically shortens routine plant maintenance cycles.
Rotodynamic fluid mechanics dictate that internal hydraulic losses scale rapidly whenever flow separation occurs within the suction eye or along the discharge diffusion cone. Through computational fluid dynamics profiling, the internal hydraulic passage angles are matched to clean water boundary layer kinetics. This careful hydrodynamic refinement prevents localized pressure drops, minimizes the formation of vapor cavities, and stabilizes flow vectors across both standard two-pole and four-pole operational speed envelopes.

Specifications / Technical Parameters / Technical Data - Tri-Tier Impeller Rating Matrix
Selecting an appropriate IS End Suction Centrifugal Pump requires evaluating plant head-capacity curves against three distinct impeller configurations: standard full-diameter geometries, primary diameter-trimmed variants (Trim-A), and secondary diameter-trimmed variants (Trim-B). In accordance with classic centrifugal affinity laws, impeller tip speed directly governs generated pressure and volumetric rate. By trimming the outer diameter while retaining internal vane camber, fluid engineers can align pump discharge pressure precisely with pipeline system resistance lines, eliminating power-wasting discharge valve throttling and ensuring the driving motor operates at the Peak Efficiency Point (BEP). Below are the dedicated technical parameter tables for each impeller classification, structured consecutively for engineering clarity.
2.1 Baseline Uncut Full-Diameter Impeller Models (Category 1: Full-Size Hydraulic Baseline)
The full-size baseline category operates with the maximum nominal impeller radius engineered for each volute casing casting. These models deliver maximum head development and elevated flow rates, making them suitable for long-distance municipal trunk mains, high-elevation pressure boosting, and large-scale agricultural distribution schemes.

|
Hydraulic Model |
Nominal Speed (rpm) |
Rated Flow (m³/h) |
Rated Head (m) |
BEP Efficiency (%) |
NPSHr Margin (m) |
Mating Motor (kW) |
Flange Bore (DN mm) |
|
IS 80-65-125 |
2900 rpm |
50.0 m³/h (rated) |
20.0 m (rated) |
75.0% BEP |
3.0 m |
5.5 kW (Y132S1-2) |
DN 65 / DN 40 |
|
IS 80-50-200 |
2900 rpm |
50.0 m³/h (rated) |
50.0 m (rated) |
69.0% BEP |
2.5 m |
15.0 kW (Y160M1-2) |
DN 80 / DN 50 |
|
IS 100-80-160 |
2900 rpm |
100.0 m³/h (rated) |
32.0 m (rated) |
78.0% BEP |
4.0 m |
15.0 kW (Y160M2-2) |
DN 100 / DN 80 |
|
IS 125-100-200 |
2900 rpm |
200.0 m³/h (rated) |
50.0 m (rated) |
81.0% BEP |
4.5 m |
45.0 kW (Y225M-2) |
DN 125 / DN 100 |
|
IS 125-100-250 |
1450 rpm |
100.0 m³/h (rated) |
20.0 m (rated) |
76.0% BEP |
2.5 m |
11.0 kW (Y160M-4) |
DN 125 / DN 100 |
|
IS 150-125-250 |
1450 rpm |
200.0 m³/h (rated) |
20.0 m (rated) |
81.0% BEP |
3.0 m |
18.5 kW (Y180L-4) |
DN 150 / DN 125 |
Uncut full-diameter pump units operate at both two-pole rotational velocity (2900 rpm) for steep dynamic head generation up to 57.5 meters, and four-pole velocity (1450 rpm) for quiet, high-volume displacement reaching 240 m³/h with exceptionally gentle suction requirements (NPSHr down to 2.5 m). Peak hydraulic conversion efficiencies span from 69.0% to 81.0%, guaranteeing efficient kilowatt utilization.
2.2 Primary Trimmed Impeller Models (Category 2: Trim-A First-Stage Impeller Trimming Matrix)
The Trim-A classification represents an engineered first-step outer diameter reduction. By machining the peripheral tip diameter of the enclosed impeller, developed discharge head is proportionally lowered. This modification serves pumping circuits where full-diameter pressures exceed system limits, avoiding excessive valve regulation and downsizing required motor horsepower.
|
Hydraulic Model |
Nominal Speed (rpm) |
Rated Flow (m³/h) |
Rated Head (m) |
BEP Efficiency (%) |
NPSHr Margin (m) |
Mating Motor (kW) |
Flange Bore (DN mm) |
|
IS 80-65-160A |
2900 rpm |
45.0 m³/h (rated) |
27.0 m (rated) |
72.0% BEP |
2.5 m |
5.5 kW (Y132S1-2) |
DN 80 / DN 65 |
|
IS 100-65-200A |
2900 rpm |
93.5 m³/h (rated) |
44.0 m (rated) |
75.5% BEP |
3.6 m |
18.5 kW (Y160L-2) |
DN 100 / DN 65 |
|
IS 100-80-160A |
2900 rpm |
93.5 m³/h (rated) |
28.0 m (rated) |
77.5% BEP |
4.0 m |
11.0 kW (Y160M1-2) |
DN 100 / DN 80 |
|
IS 125-100-200A |
2900 rpm |
187.0 m³/h (rated) |
44.0 m (rated) |
79.0% BEP |
4.5 m |
37.0 kW (Y200L2-2) |
DN 125 / DN 100 |
|
IS 100-65-250A |
1450 rpm |
46.0 m³/h (rated) |
17.5 m (rated) |
65.5% BEP |
2.0 m |
4.0 kW (Y112M-4) |
DN 100 / DN 65 |
|
IS 150-125-250A |
1450 rpm |
187.0 m³/h (rated) |
17.5 m (rated) |
77.0% BEP |
3.0 m |
15.0 kW (Y160L-4) |
DN 150 / DN 125 |
Because the inner shroud profiling and vane entry angles remain undisturbed, Trim-A models sustain optimal hydraulic performance within an tight envelope of the uncut baseline. Drive motor frame sizing drops accordingly-for instance, unit IS 125-100-200A downscales power demand from 45.0 kW to 37.0 kW, yielding significant cumulative electrical savings across continuous plant operational hours.
2.3 Secondary Trimmed Impeller Models (Category 3: Trim-B Deep Energy Optimization Matrix)
The Trim-B series incorporates a calculated second-stage diameter reduction tailored for piping installations with lower static elevation lift or compact loop geometry. Operating oversized pumps against heavy throttle valves incurs severe hydraulic turbulence and wasted kilowatt-hours; Trim-B units deliver natural duty matching with downsized motor frames.
|
Hydraulic Model |
Nominal Speed (rpm) |
Rated Flow (m³/h) |
Rated Head (m) |
BEP Efficiency (%) |
NPSHr Margin (m) |
Mating Motor (kW) |
Flange Bore (DN mm) |
|
IS 80-65-125B |
2900 rpm |
43.4 m³/h (rated) |
14.6 m (rated) |
71.0% BEP |
3.0 m |
3.0 kW (Y100L-2) |
DN 80 / DN 65 |
|
IS 80-50-200B |
2900 rpm |
41.5 m³/h (rated) |
38.0 m (rated) |
66.0% BEP |
2.5 m |
7.5 kW (Y132S2-2) |
DN 80 / DN 50 |
|
IS 100-65-200B |
2900 rpm |
86.6 m³/h (rated) |
38.0 m (rated) |
74.0% BEP |
3.6 m |
15.0 kW (Y160M2-2) |
DN 100 / DN 65 |
|
IS 125-100-200B |
2900 rpm |
158.0 m³/h (rated) |
35.0 m (rated) |
75.5% BEP |
4.5 m |
22.0 kW (Y180M-2) |
DN 125 / DN 100 |
|
IS 100-65-250B |
1450 rpm |
41.0 m³/h (rated) |
15.0 m (rated) |
62.5% BEP |
2.0 m |
3.0 kW (Y100L2-4) |
DN 100 / DN 65 |
|
IS 125-100-250B |
1450 rpm |
86.5 m³/h (rated) |
15.0 m (rated) |
75.5% BEP |
2.5 m |
5.5 kW (Y132S-4) |
DN 125 / DN 100 |
With electrical drive selections scaled between 3.0 kW and 22.0 kW, Trim-B assemblies maximize thermal and economic efficiency. Model IS 125-100-200B delivers up to 190 m³/h volumetric output at 35.0 m head while requiring only 22.0 kW motor input, offering a substantial reduction from the baseline 45.0 kW configuration while preserving stable cavitation-free operation.
Quality Assurance - Hydrostatic Shell Proof, Dynamic Balancing, and ISO 9906 Factory Acceptance
Industrial fluid equipment reliability demands rigorous factory quality verification before field dispatch. In municipal waterworks, cooling towers, and continuous processing plants, structural casing flaws, chronic shaft seal weeping, or excessive rotational vibration produce costly production disruptions. To eliminate operational uncertainty, our manufacturing protocol incorporates comprehensive non-destructive examination, pressure boundary integrity proofing, computerized rotor balancing, and automated closed-circuit hydraulic acceptance tests.
Every production-line IS End Suction Centrifugal Pump undergoes rigorous pressure testing pressurized to one-and-a-half times nominal operating threshold (typically 2.4 MPa) with an extended dwell duration of thirty minutes. This hydraulic proof test validates the dense microstructure of grey cast iron (HT200/HT250), ductile nodular iron (QT450), or cast stainless steel casings, ensuring zero porosity, micro-fissuring, or wall seepage. Flange sealing faces, tapping points, and casing wall thickness reserves are thoroughly inspected under full test pressure prior to surface blasting and epoxy finishing.
Rotating assembly stability is maintained through dual-plane dynamic balancing performed in strict alignment with ISO 1940 Grade G2.5 specifications. Impeller castings are dynamically balanced on computerized electronic balancing machines, correcting minor mass eccentricities through precision shroud trimming. Controlled dynamic balancing suppresses structural harmonics, protects heavy-duty radial deep-groove ball bearings against premature spalling, and extends mechanical seal face longevity across thousands of operating hours.
Final factory acceptance testing takes place on automated, instrumented closed-circuit testing benches adhering to hydraulic acceptance criteria under ISO 9906 class 2B. Electromagnetic flow sensors, precision pressure transmitters, and digital power meters record head-capacity curves, absorbed brake horsepower, hydraulic conversion efficiency, and suction margins across five discrete test points. Factory test certificates, dimensional inspection records, and metallurgical dossiers (EN 10204 3.1) accompany every international consignment.
Additionally, every batch of grey iron and nodular iron melts is verified via optical emission spectrometry to confirm pearlitic matrix density, graphite flake dispersion, and minimum tensile yield properties prior to pouring. Casing thickness across the volute tongue and suction nozzle neck is cross-checked using ultrasonic thickness gauges to ensure robust safety margins against water hammer surges.

Application - Municipal Potable Distribution, Hydronic HVAC, Agricultural Pumping & Industrial Water Utility
Benefiting from standardized ISO 2858 mechanical geometry, predictable hydraulic curves, and accessible field servicing, the IS End Suction Centrifugal Pump demonstrates proven reliability across a wide range of utility environments:
• Municipal Water Utility & Potable Boosting: Deployed within regional drinking water processing stations, municipal clear-water transfer pumping vaults, and high-elevation water tower distribution manifolds. Stable hydraulic efficiency guarantees economical 24/7 continuous water delivery.
• Commercial & District Hydronic HVAC: Operates in central chilled water loops, evaporative condenser circulation, boiler feed water pressurization, and multi-building district hydronic heating networks. Balanced rotor dynamics ensure low acoustic emissions inside commercial facilities.
• Agricultural Irrigation & Rural Water Conveyance: Handles raw surface water intake from irrigation rivers, canal lift stations, automated center-pivot spray rigs, and orchard drip filtration lines. Generous suction lift margins comfortably accommodate changing seasonal water tables.
• Industrial Plant Utilities & Auxiliary Cooling: Circulates non-abrasive process cooling water for automotive stamping presses, foundry cooling circuits, textile dyeing utilities, and paper mill processing loops requiring continuous S1 duty dependability.
• Industrial Firefighting & Standby Booster Skids: Installed as primary electric motor-driven or backup diesel engine-driven fire booster pumps for industrial logistics parks, manufacturing warehouses, and energy storage yards.
• Mine Dewatering & Camp Utility Systems: Transports treated surface water, camp utility supply, and intermediate clarification runoff across surface quarry facilities and mineral processing utility stations.

Our Service - Pre-Engineering Hydraulic Sizing, Custom Drive Packaging & Worldwide Spare Parts Delivery
Procuring heavy-duty pumping equipment involves extensive technical coordination beyond standard catalog selection. Our engineering division delivers complete lifecycle technical support from early hydraulic modeling through to on-site commissioning and long-term aftermarket spares logistics:
• Application Engineering & System Head Modeling: Our technical staff performs friction loss modeling and NPSHa margin calculations, ensuring pump selections align precisely with system resistance curves without risk of cavitation or motor overloading.
• Custom Skid Packaging & Baseplate Fabrication: We assemble complete pumping packages mounted on rigid channel-steel skid bases, coupled to premium IEC high-efficiency electric motors (IE3/IE4), flameproof drives (ATEX/IECEx), or diesel power units via flexible pin-bush couplings with OSHA-compliant safety shields.
• Specialized Metallurgy for Corrosive Water Chemistry: In addition to standard high-grade grey iron, we cast impellers in tin bronze (ZCuSn10Pb1) or cast iron components in ductile nodular iron (QT450) and 304/316 austenitic stainless steel for brackish river water or mildly acidic processing streams.
• Engineered Shaft Sealing Configurations: Stuffing boxes are readily configured with braided PTFE-graphite packing rings and lantern flush ports, or single/cartridge mechanical seals featuring silicon carbide friction faces (SiC/SiC) and viton secondary elastomers.
• Expedited International Spare Parts Support: High-wear components-including bronze wear rings, stainless shaft sleeves, mechanical seal packs, and bearing assemblies-are maintained in extensive factory inventory for rapid overseas fulfillment.
• On-Site Alignment & Field Commissioning Guidance: We furnish detailed laser shaft alignment guidelines, baseplate grouting specifications, and vibration baseline monitoring protocols to ensure smooth handover and trouble-free initial startup.

Experience and Markets - Over 30 Years of Rotodynamic Manufacturing & 50+ Export Destinations
With a solid manufacturing foundation spanning over 30 years in rotodynamic fluid machinery, our manufacturing organization has supplied proven centrifugal pumping solutions to infrastructure and commercial clients worldwide. Operating from our specialized industrial production hub, we have successfully completed fluid handling supply contracts across more than 50 export destination countries spanning Southeast Asia, Central Asia, the Middle East, Latin America, Eastern Europe, and Africa.
Our export portfolio encompasses challenging field environments-including municipal waterworks projects in the Philippines and Indonesia, mining camp utility supplies in Central Africa, and agricultural irrigation infrastructure throughout Central Asia and South America. Certified to ISO 9001 quality management standards, EAC Eurasian conformity guidelines, and RoHS European standards, our factory delivers verified mechanical reliability that satisfies strict international procurement audits.
Through decades of direct interaction with consulting engineers and global plant managers, we have tailored our documentation, factory acceptance procedures, and logistics packaging to align seamlessly with FIDIC and international EPC contract standards. This proven track record ensures predictable project execution from initial tender submission through long-term commercial operation.

FAQ - High-Intent Engineering & Procurement Questions for Industrial Pump Buyers
Q1: What differentiates the IS End Suction Centrifugal Pump from double-suction or multistage configurations?
The IS model is a single-stage, single-suction horizontal overhung pump engineered to ISO 2858 standards. Double-suction split-case pumps (such as the S/SH series) feature liquid entering both sides of an impeller within a horizontally parted casing, primarily used for massive volumetric flows exceeding 400 m³/h. Multistage pumps utilize multiple impellers in series to generate extreme discharge pressures exceeding 150 meters head. The IS end-suction configuration represents the most economical, compact, and easily serviced solution for clean water handling across flows up to 240 m³/h and heads up to 57.5 meters, offering the lowest capital cost and simplest piping layout.
Q2: How does the Back-Pull-Out mechanical design streamline maintenance routines?
In conventional industrial piping layouts, servicing an internal rotor necessitates unbolting pipe flanges and disconnecting motor cabling. The back-pull-out geometry of the IS pump allows the bearing pedestal, drive shaft, seal plate, and impeller to be retracted rearward without detaching the volute casing from suction and discharge headers. When combined with a spacer-type flexible coupling, maintenance crews can inspect seals and replace bearings without unbolting or shifting the electric motor.
Q3: Under what operating criteria should designers select Trim-A or Trim-B impellers instead of uncut impellers?
Uncut baseline impellers provide maximum dynamic head and capacity. However, when actual pipeline friction head is lower than the uncut curve delivers at rated flow, running an uncut impeller forces operators to restrict discharge valves. This artificial throttling converts valuable electrical energy into useless fluid friction. Specifying a factory Trim-A or Trim-B impeller lowers developed head directly at the source, matching system friction lines and shrinking motor kilowatt consumption while operating at the Peak Efficiency Point (BEP).
Q4: What are the allowable operating boundaries regarding liquid temperature and suction capability?
Standard gland-packed IS units handle non-aggressive clear water between -10°C and +80°C. For elevated thermal duties up to +120°C (such as boiler feedwater or district heating loops), pumps are fitted with balanced mechanical seals and optional water-cooled stuffing boxes. Depending on rotational speed, Net Positive Suction Head required (NPSHr) spans between 2.0 m and 4.5 m. Suction piping layouts should maintain at least a 0.5 m to 1.0 m positive buffer between NPSHa and NPSHr to prevent cavitation pitting.
Q5: What protective packaging and commercial documentation accompany export shipments?
All export machinery is treated with internal anti-corrosion barrier oil, sealed with waterproof vapor-barrier film, and secured inside heavy-duty fumigated wooden crates engineered for maritime container transport or air transit. Deliveries are quoted strictly on FOB or CIF destination port terms. Each shipment includes certified factory test reports, material traceability dossiers, dynamic balancing certificates, operation and maintenance manuals, and comprehensive export packing lists.

Hot Tags: is end suction centrifugal pump, China is end suction centrifugal pump manufacturers, suppliers, factory