Commissioning and Operation of Slurry Pumps

Oct 04, 2026

Leave a message

The trial run of a slurry pump must meet the following requirements:
(1) The direction of rotation of the drive motor must match that of the pump.
(2) All fixed connections must be secure; the type and quantity of lubricant applied to all lubrication points must comply with the specifications in the equipment's technical documentation.
(3) Components requiring pre-lubrication must be lubricated in accordance with the specified procedures.
(4) All instrumentation and safety protection devices must be responsive, accurate, and reliable.
(5) The pump shaft should rotate freely when turned manually, with no signs of irregularities.
(6) For high-temperature pumps, the pump casing must be preheated prior to the trial run. The temperature should rise uniformly at a rate not exceeding 50°C per hour. The temperature difference between the pump casing surface and the process piping at the working medium inlet must not exceed 40°C.
(7) Connection devices designed to compensate for thermal expansion must be in place, and a bypass connection should be provided to supply cooling water.
During the operation of a slurry pump, the following points should be observed:
(1) Dry running (operation without liquid) is prohibited. Do not adjust the suction inlet to reduce flow rate, and avoid operating the pump at an excessively low flow rate.
(2) Monitor the pump during operation. Ensure there is no leakage from the stuffing box; always use new packing material when replacing the packing.
(3) Ensure an adequate flow of flushing water for mechanical seals. For water-cooled bearings, avoid using an excessive volume of cooling water.
(4) Do not over-apply lubricant.
(5) Conduct inspections according to recommended intervals. Maintain operational records, including total operating hours, details on packing adjustments or replacements, lubricant additions, and other maintenance activities. Regularly measure and record parameters such as suction and discharge pressure, flow rate, input power, temperatures (of flushing fluid and bearings), and vibration levels.

Send Inquiry