During the installation of a slurry pump, the following checks must be performed:
(1) The dimensions, position, and elevation of the foundation must comply with design requirements; anchor bolts must be properly and correctly secured within the concrete foundation; and the equipment must be free of missing parts, damage, or corrosion.
(2) Depending on the characteristics of the medium being transported by the slurry pump, the materials of key components, shaft seals, and gaskets should be verified, if necessary.
(3) The leveling and alignment of the slurry pump must conform to the equipment's technical specifications. In the absence of such specifications, they must comply with the current national standard, "General Code for Construction and Acceptance of Mechanical Equipment Installation Engineering."
(4) The installation of all piping and fittings connected to the slurry pump, as well as the cleaning requirements for lubricating oil piping, must adhere to the relevant national standards.